security
3.1.1
AUTOMATIC FOR PARKS operating
One pulse allows : opening , pause , automatic closing .
During the opening operation, other pulses will be ignored. During the closing operation,
possible pulses stop and reverse the movement of gate immediately.
A contact closed on PULSE A ( Clock function ) allows to open the gate up to the setted pause
and it be open up to the opening of the contact.
GATE
PULSE A
STATUS
Total Opening and
CLOSE
reclosing after the time
No effect if the opening
is started by the
OPENING
Total Opening if the
opening is started by
the PULSE B
PARTIAL
Total Opening
OPEN
IN PAUSE
TOTAL
The reclosing is stopped and at the end of the
OPEN
pause, it restores other 5 sec. up to the reset
IN PAUSE
The closing is stopped and the gate opens
CLOSING
Restarts the operating procedure before the
IN STOP
3.1.2
AUTOMATIC operating
With one pulse allows :opening, pause, automatic closing.
During opening and closing procedures, every pulse stops and reverse the movement of the
gate immediately.
During the pause, a pulse recloses the gate immediately.
GATE
PULSE A
STATUS
Total Opening and
CLOSE
reclosing after the time
The gate stops and it recloses immediately.
OPENING
OPEN
IN PAUSE
CLOSING
The gate stops and it opens immediately.
Restarts the operating procedure before the
IN STOP
All manuals and user guides at all-guides.com
PULSE B
Partial Opening and
closing operation after
the time of pause
of pause
PULSE A
No Effect
The reclosing is stopped
and at the end of the
pause it restores other 5
sec. up to the reset
again immediately
STOP (closing or opening)
( SW1=ON - SW2=OFF)
PULSE B
Partial Opening and
reclosing after the time
of pause
of pause
The gate recloses immediately
STOP (closing or opening)
(SW1=OFF - SW2=OFF)
STOP
PHOTOCELL 1 PHOTOCELL 2
Disables A and B pulses
and disable opening
The reclosing is stopped and at the end of the
Stops operation
pause, it restores other 5 sec. up to the reset
and switches to
STOP mode
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
Stops operation and the gate opens immediately
Remain in STOP. The pulses A and B will be ignored.
The opening or closing operation are locked
STOP
PHOTOCELL 1 PHOTOCELL 2
Disables A and B pulses
and disable opening
Stops operation
The reclosing is stopped and at the end of the
and switches to
pause, it restores other 5 sec. up to the reset
STOP mode
Stops operation and the gate opens immediately
Remain in STOP. The pulses A and B will be ignored.
The opening or closing operation are locked
Setup
ON
See SWITCH 3 page 10
See switch 3 page 10
A total opening is possible.
in open operation
ON
See SWITCH 3 page 10
See switch 3 page 10
in open operation
27