AXIS P1355/P1357 Installation Guide
Function
Pin
Notes
GND
1
Ground
3.3 V DC
2
Can be used to power auxiliary equipment.
Power
Note: This pin can only be used as power out.
Digital
3
Connect to GND to activate, or leave floating
Input
(unconnected) to deactivate.
Digital
4
Uses an open-drain NFET transistor with the source
Output
connected to GND. If used with an external relay, a
diode must be connected in parallel with the load,
for protection against voltage transients.
The following connection diagram gives an example of how to connect an auxiliary device to the
network camera.
3.3V
max. 50mA
All manuals and user guides at all-guides.com
1
2
3
4
D
G
S
Page 11
Specifications
Max load = 50 mA
Min. input = -40 V DC
Max. input= +40 V DC
Max. load =100 mA
Max. voltage = + 40 V DC