MAINTENANCE AND SERVICE

SERVICING AND CHANGING THE CLAMP-
ING JAWS
Depending on the mandrel material, shear force
and surface finish, the clamping jaws have to be
cleaned and replaced at regular intervals.
Changing and servicing the clamping jaws requires
no tools.
I
To change the clamping jaws, press trigger (I)
and hold it depressed. With the other hand,
loosen union nut (V) connecting front sleeve
(B) and mouthpiece (A).
II
Remove union nut (V) and release trigger (I).
III Remove front sleeve (B) together with mouth-
piece (A).
IV Clamping sleeve (3) is held by a spring-loaded
(1) fastener (2).
V
Push fastener (2) towards riveter housing (P)
and unscrew clamping sleeve (3).
VI Remove clamping jaws (5) from clamping
sleeve (3). Thoroughly clean the inside and
outside of clamping jaws (5) and clamping
sleeve (3). Always replace a complete set of
worn clamping jaws (5). Grease the inside of
clamping sleeve (3) lightly with pressure-resist-
ant grease using a brush (4).
Install clamping jaws (5) in the clamping sleeve
again and fit the clamping mechanism again in the
reverse order.
Important note: Screw on the clamping sleeve up
to the first slight resistance.
Let go of the quick release mechanism and
unscrew the clamping sleeve again until the quick
release mechanism engages.
RIVETER SERVICE
In order to ensure proper and safe operation of the
riveter, it should be sent to a service centre either
directly or via your dealer. The terms of the warran-
ty extension must be observed.
48 | English
What?
Who?
Visual inspec-
Operator
tion of the
riveter
Battery
Operator
charge state
Calibration
Operator
Operator
Cleaning and
greasing the
clamping
mechanism
Changing the
Operator
clamping jaws
Changing the
Operator
mouthpiece
Inspection
VVG Service
BATTERY
The battery (F) has a latch (G) on the front side.
To insert or remove the battery, press the latch (G)
downwards and push the battery (F) into the riveter
foot or pull it out.
Use the battery (F) in the riveter only in the speci-
fied temperature range between -5 and 45 °C.
Charge the battery (F) only in a temperature range
between 0 and 40 °C.
Use only the approved charger.
Never short-circuit the battery (F).
If the battery (F) shows signs of visible damage, do
not use it any longer.
Keep the battery (F) away from moisture and
liquids.
Dispose of the battery (F) in the proper manner.

BATTERY STORAGE

Protect the battery (F) from moisture and liquids.
Store the battery (F) only in the optimum tempera-
ture range between -30 °C and 25 °C. The battery
(F) can be stored as follows without recharging:
Storage period between -30 ~ 25 °C – 1.5 years
Storage period between -30 ~ 45 °C – 3 months
Storage period between -30 ~ 60 °C – 1 month
Do not leave the battery (F) in the car, e.g. in the
summer.
A significantly shorter operating time after recharg-
When?
Daily
Daily
Daily, when
working with
DMSD Lite
Between 1,000
and 10,000,
depending on
the rivet type
When the rivet
can no longer
be set in one
stroke
Every 25,000
to 50,000 rivets
300,000 or
18 months