Télécharger Imprimer la page

Napoleon PATIOFLAME GPFR60 Mode D'emploi page 10

Foyers extérieurs au gaz

Publicité

Les langues disponibles

Les langues disponibles

10
Enclosures For LP (Propane) Gas Supply Systems
If you build an enclosure for an LP gas cylinder, follow these recommended specifications. You must also
EN
follow local codes.
An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels
of
This shall be accomplished by one of the following:
One side of the enclosure shall be completely open;
OR
For an enclosure having four sides, a top, and a bottom:
a) At least two ventilation openings shall be provided in the sidewalls of the enclosure, located within 5 in
(127 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and
unobstructed. The opening(s) shall have a total free area of not less than 1 in
stored fuel capacity.
b) Ventilation opening(s) shall be provided at floor level of the enclosure and shall have a total free area of
not less than 1/2 in
a side wall, there shall be at least two openings. The bottom of the openings shall be 1 in (25.4 mm) or less
from the floor level and the upper edge no more than 5 in (127 mm) above the floor level. The openings
shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed.
c) Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2mm)
diameter rod.
Ventilation openings in sidewalls shall not communicate directly with other enclosures of the
appliance.
Cylinder valves shall be readily accessible for hand operation. A door on the enclosure to gain access to
the cylinder valve is acceptable, provided it is non-locking and can be opened without the use of tools.
Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or
equivalent at a minimum of 180 degrees apart to facilitate lifting of the cover.
There shall be a minimum clearance of 2 inches (50.8mm) between the lower surface of the floor of the LP
gas supply cylinder enclosure and the ground.
The design of the enclosure shall be such that (1) the LP gas supply cylinder(s) can be connected,
disconnected and the connections inspected and tested outside the cylinder enclosure; and (2) those
connections which could be disturbed when installing the cylinder(s) in the enclosure can be leak tested
inside the enclosure.
The enclosure for the LP-gas cylinder shall isolate the cylinder from the burner compartment to provide:
a. Shielding from radiation;
b. A flame barrier; and
c. Protection from foreign material.
Be certain to mount or set the LP gas cylinder on a flat surface. The LP gas cylinder enclosure must be
designed and constructed with means which limit the movement of the cylinder, such as a retaining
bracket. Whichever means of retention are selected, they must:
Position the cylinder a minimum of 3 1/4" (8cm) from the base of the appliance as indicated in the
diagram on pg. 11.
Prevent the cylinder from tipping over if it is brought to an angle of 30⁰ and released.
Prevent lateral movement of the cylinder (both empty and full) in excess of 1" (25.4mm) at the point
where the retention means are affixed, when a force equal to the weight of a full cylinder is applied in
any direction at the center of the vertical height of the cylinder.
No cylinder, or any part of the cylinder, is permitted to become dislodged from the retention means under
any conditions outlined above. Any movement must not transmit strain to hoses, rigid tubing, or gas
connections. If securing means are attached to the protective collar or foot ring of the cylinder, they must
not depend on openings in the protective collar or the foot ring, and must not interfere with the operation
of the cylinder valve.
www.napoleongrills.com
N415-0310 Jan 11.19.indd 10
the enclosure.
2
2
per lb (7.1 cm
/ kg) of stored fuel capacity. If ventilation openings at floor level are in
2
2
per lb (14.2 cm
/ kg) of
N415-0310 Jan 11.19
11/01/2019 2:11:02 PM

Publicité

loading

Ce manuel est également adapté pour:

Patioflame gpfs60623893