Troubleshooting, Cleaning
5. Manual calibration
→ Fresh and dry outdoor air is required for manual calibration when the CO
value is approx. 500 ppm. Do not calibrate the detector in the rain.
High humidity increases the CO
2
manually, keep the detector away from areas where there are many people
or objects that
could emit CO
, such as ventilation pipes, chimneys or cars.
2
To calibrate manually, place the detector outdoors and press the three
buttons
simultaneously. "CO2" will flash during calibration,
which lasts approx. 16 minutes until the flashing stops. Calibration is
completely automatic.
Cleaning
· Dusty detectors have to be cleaned.
Dust deposits in the air inlets of the detector can be vacuumed or blown out.
· If necessary, you can remove the dust with a brush.
· The surface can be cleaned using a cloth lightly moistened with soapy water.
· Do not allow water to enter the inside of the device!
· Do not clean the device in a dishwasher!
· Do not use sharp, pointed, abrasive, or corrosive cleaning materials or hard
brushes!
· Do not use chemicals and do not clean the detector with highly flammable
liquids!
content in the air. When calibrating
– 30 –

Technical data

2
Power supply
Emergency power supply
CO
sensor type
2
CO
sensor lifespan*
2
Operating temperature
Humidity
Installation location
CO
measurement range
2
CO
dissolution
2
CO
accuracy
2
Air quality / CO
concentration
2
Alarm triggering
* End of sensor lifespan
Since the electrochemical sensor is subject to ageing processes, the lifespan of
the CO
sensor is a maximum of 10 years. When the detector has reached the
2
end of its lifespan, it must be replaced.
AC adapter input: AC 100~240V
Output DC 5V/1A Micro-USB
1000mAh 3.7V lithium-ion battery
(built in)
non-dispersive infrared (NDIR) sensor
max. 10 years
-10° to 40° C
0 % to 95 % (non-condensing)
Wall or stand-alone mounting
0-5000 ppm
1 ppm
100 ppm or 10% of the measured values,
whichever is higher
good: < 600 ppm*
normal: 600-1200 ppm*
poor: > 1200 ppm*
* Values can be adjusted on the CO2 setup
page
> 1200 ppm (can be adjusted on the
CO2 setup page)
– 31 –