Determination of the pressure loss in relation to the flow rate.
The values described in the diagram have been obtained with:
an upstream pressure of 8 bar (800 kPa)
the pressure reducer calibrated on 3 bar (300 kPa)
Pressure loss bar
Pressure loss bar
CONSTRUCTIONAL FEATURES
Body
Metal used for inner parts
Internal cartridge
Filter
Gaskets
External plastic parts
Pressure gauge-holder connection
Connections
FF UNI-EN-ISO 228 (series 2848)
MM UNI-EN-ISO 228 (series 2909)
1 "
3/4 "
1/2 "
2 "
1 "1/2
1 "1/4
CW 602 N UNI EN 12165 Brass
CW 614 N UNI EN 12164 Brass
CW 602 N UNI EN 12164 Brass
POM
AISI 302 stainless steel
EPDM PEROX
Nylon 6 with 30% glass fibre
F G 1/4"
INSTALLATION RECOMMENDATIONS:
install – upstream and downstream of the reducer – the shut-off valves
to perform any maintenance work;
always envisage the application of a filter upstream of the system;
thoroughly clean the high-pressure pipe upstream of the reducer by
flushing several times;
follow the direction indicated by the arrow on the body;
set the reducer to the maximum pressure compatible with the system,
fully open the downstream flush valve to further clean the pipe;
close the downstream valves and set the reducer to the desired
pressure, shown on the pressure gauge that can be applied to the
manometric intake by removing the cap;
flush a few times to check the stability of the setting;
if the system includes tanks or devices with an operating pressure
lower than the pressure of the network upstream of the reducer, when
this is installed always fit the safety valves required to protect the
tanks or devices.
WARNING: When the system is running, the pressure detected by the
pressure gauge may be affected by the overpressure of the heating
system; any adjustments must be performed when the system is not
running and at ambient temperature.
The pressure reducing valve can be installed horizontally and vertically.
OK
TECHNICAL FEATURES
Compatible fluid
Nominal pressure
Maximum upstream pressure
Adjustable downstream pressure
Factory presetting
(with 8 bar downstream pressure)
Maximum operating temperature
OK
Water
PN25 (cold water 40°C)
PN16 (hot water 80°C)
25 bar (cold water 40°C)
16 bar (hot water 80°C)
0,8÷7 bar (80÷700 kPa)
3 bar (300 kPa)
80°C