Installation instructions, only for experts
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instruc-
tions for the device.
2. Guide the wires for the safety shut-off device through the cable bushing
into the low-voltage connection area
3. Connect the wires to the terminals labelled "OSG" in terminal strip
If a safety shut-off is not installed, a jumper must be fitted at the terminals
labelled "OSG".
5.7. Remote start
This is connected using terminals "S" and "B". "S" stands for sauna mode. "B"
is a +24 V DC output. This must be activated using a switch or an actuator on
terminal "S".
5.8. Finishing installation
1. Connect the earth conductor for the power supply cable and all devices to
the earth rail
g
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.
.
.