LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and
pull it out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure
that the two pins are properly inserted in the lamp
holder socket holes.
• Refit the Support, fixing it in place with the two
screws removed as above.
Lamp
Power (W)
28
20
35
50
20
20
16
18
9
11
EN
Lighting
Socket
Voltage (V)
E14
220 – 240
G4
12
GU10
230
GU10
230
GU4
12
GU5.3
12
G13
95
G13
57
60 (lamp)
G23
220-240 (starter)
91 (lamp)
G23
220-240 (starter)
Dimension (mm)
HSGSB/C/UB-28-220/240-E14
104 x 35
33 x 9
HSG/C/UB-20-12-G4
51 x 50,7
HAGS-35-230-GU10-51/40
51 x 50,7
HAGS-35-230-GU10-51/20
40 x 35
HRGS-20-12-GU4-35/30
46 x 51
HRGS-20-12-GU5.3-50/10
720 x 26
FD--16/40/1B-E--G13--26/720
589,8 x 26
FD--18/40/1B--E--G13--26/600
167 x 28
FSD-9/27/1B-I-G23
235,8 x 28
FSD-11/40/1B-I-G23
ILCOS Code