Elkron EIR600 Guide Rapide page 4

Détecteur infrarouge pour extérieur avec fonction pet
Masquer les pouces Voir aussi pour EIR600:

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
1. Test button and LED
2. Double sensor
3. Battery housing for two AA 3.6 V lithium batteries.
LED
In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations.
When movement is detected in flat battery conditions.
When the cover is opened and the tamper switch is actuated.
When movement detected if the tamper alarm condition persists.
When motion is detected in Test mode.
When the Test button is pressed in tampering conditions or if the battery of the device is flat.
The LED does not blink if the tamper switch is closed, the battery is charged and the detector is not in Test mode.
The LED blinks to indicate signal transmission, blinking rapidly twice upon receiving confirmation from the control unit.
DIP Switch position table
The function of each DIP Switch is listed in the following table. The DIP Switch is in position ON or OFF. Position up indicates
ON, position down indicates OFF.
DIP
Position
Function
ON
Test mode
Switch1
OFF
Normal mode (default)
position
ON
Supervision off
Switch2
OFF
Supervision on (default)
position
Detector facing a closed space (eg a wall higher
ON
than a person within 10 m of the detector)
Switch3
Detector facing an open space (no wall within
OFF
10 m of the detector) (default)
Detector facing a surface that does not easily
ON
release heat (eg a lawn) (default)
Switch4
OFF
Detector facing a surface that easily releases
position
heat (eg in cement, or stone or tiled)
Preparation – Learning of the detector by the control unit
Loosen the screws and remove the cover.
Set the sensitive switch as needed as shown in the DIP Switch position table.
Insert two AA 3.6 V lithium batteries in the battery housing ensuring that the polarity is correctly connected.
The LED indicator will blink for 30 seconds. The detector is being initialised. During initialisation, the detector will not be
active. It is advisable not to generate any alarms during this time. Once the initialisation time has finished, the LED will
switch off and the detector is ready to start working.
Set the control unit to learning mode; see the instruction manual of the control unit for details.
Hold the Test button on the front cover pressed for about 3 seconds.
The corresponding information is displayed if the control unit receives the signal. Refer to the instruction manual of the
control unit to complete the learning process.
Put the control unit in Walk Test mode (motion Test) after the detector learning procedure. Hold the detector in the
required position, press the Test button to check that the concerned position is within the communication coverage range.
Proceed with the installation after having ascertained that the detector is working in the desired position.
Test mode
The detector can be set to Test mode for three minutes by pressing the Test button once. In Test mode, the sleep time is off
and the LED indicator lights up for two seconds, independently from motion detection. The detector automatically exits Test
QUICK GUIDE
EIR600
OUTDOOR IR DETECTOR WITH PET FUNCTION
Coverage diagram
Installation height / Range
4. Tamper switch
5. DIP Switch block
6. Bracket arm
7. Rotating bracket
DIP
Sensitivity level
Switch5
Switch6
ON
ON
Low; for 75 cm / 60 kg animals
OFF
ON
Medium; for 60 cm / 40 kg animals
position
OFF
ON
High; for 45 cm / 30 kg animals
position
OFF
OFF
Higher; for 30 cm / 20 kg animals
position
position
(default)
DIP
Position
Function
ON
Double detection on (default)
Switch7
OFF
Double detection off
position
ON
Switch8
Reserved
OFF
DS80IR2F-002A