Télécharger Imprimer la page

eurodib T-HP212 Instructions D'installation Et D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

MODEL
WIDTH
IN. (MM)
T-HP212
12(305)
T-HP424
24(610)
T-HP636
36(915)
Note: Depth direction includes the regulator's size.
These instructions are for the conversion from Natural Gas to Propane (L.P.) on all models.
The conversion should be done before connecting the unit to the gas supply.
Units are shipped from the factory equipped for use on natural gas. Orifices necessary for
Propane (L.P.) are provided in a bag of the manual.
1. Shut off the main isolation gas valve and follow the lock-out/tag-out procedure.
SPECIFICATION AND DIMENSIONS
DEPTH
HEIGHT
IN. (MM)
IN. (MM)
29.2(741)
18.7(475)
29.2(741)
18.7(475)
29.2(741)
18.7(475)
CONVERSION
# OF
BTU/PER
BURNERS
NAT/LP
2
30,000
4
30,000
6
30,000
5
W.C.
TOTAL
BTU/ Hr
IN.
60,000
6/10
120,000
6/10
180,000
6/10

Publicité

loading

Ce manuel est également adapté pour:

T-hp424T-hp636