INSTALLATION INSTRUCTIONS
DIXON 06-4308P
TWO HANDLE LAVATORY FAUCET
THIS FAUCET MEETS OR EXCEEDS THE FOLLOWING STANDARDS:
cUPC, ASME A112.18.1, NSF-61 AND LOW LEAD COMPLIANT
THANK YOU FOR PURCHASING THIS TAYMOR PRODUCT. ALL TAYMOR PRODUCTS ARE CAREFULLY
ENGINEERED AND FACTORY TESTED TO PROVIDE LONG TROUBLE-FREE USE UNDER NORMAL CONDITIONS.
HAVE BASIC TOOLS READY
1
RECOMMENDED TOOLS:
Teflon tape Screwdrivers
Adjustable
Flashlight
wrench and
pipe wrench
WARNING: READ ALL the instructions completely before beginning.
READ ALL warnings, care and maintenance information.
Taymor recommends calling a professional if you are uncertain about installing this product!
This product should be installed in accordance with all local and provincial plumbing and building codes.
Use only a damp cloth to clean and shine, then dry with a soft cloth. Avoid abrasive cleansers, bleach
solvents, steel or bronze wool or other chemicals which may cause damage. A finish deterioration occurring
from use of paints, solvents, cleaners, or other chemicals is not a defect and therefore is not covered by the
warranty.
Need Help? Please call our toll-free Customer Support line at
(WEST) 1-800-267-4774
(EAST ) 1-800-387-7064 for additional assistance or service.
TURN OFF THE MAIN WATER SUPPLY
2
Locate water supply inlets and shut off water supply valves. These are usually found under
the sink.
TURN OFF
GASKET & FAUCET INSTALLATION
3
A) Apply a bead of plumber's putty or silicone caulk around the sink openings.
B) Install the gasket over the three holes in your sink.
C) Ensure the handle seats and the handles are aligned as in diagram (1) by turning the handle seat if
necessary (2), the open-close turn of the handle cannot exceed 90°. Install faucet shanks through the
holes of the sink. Centre the faucet body on the sink.
Don't use plumber's putty on cultured marble or other composite sinks.
Putty will discolour the sink.
A
HAND TIGHTEN THE WING NUTS
4
From underneath the sink, hand tighten the wing nuts. Tighten gently until snug and alternate from side
to side to seat the faucet body evenly.
Don't over tighten
All manuals and user guides at all-guides.com
Your installation may require new
supply lines. (Supply lines are not
included.)
Torque wrench
Safety goggles
Plumber's putty
TURN OFF
B
C
ATTACH THE HOT AND COLD SUPPLY LINES
5
Apply Teflon tape onto threaded ends of faucet inlets.
Connect water supply lines to faucet inlets. Hot water supply lines go into left inlet. Cold water supply
lines go into right inlet. (Supply lines are not included).
FOR PLASTIC AND BRAIDED
STAINLESS STEEL SUPPLY TUBES
THESE SUPPLY TUBES HAVE INTEGRAL NUTS, SO JUST
SCREW THE NUT ONTO THE FAUCET INLET.
TORQUE
22 – 30 FT/LBS.
INSTALLING POP-UP DRAIN
6
A) Remove pop-up plunger (A) and flange (B). Screw locknut (C) all the way down. Push
gasket (D) down. Apply silicone to underside of flange (B).
B) Insert body into sink (from underneath). Screw flange onto body. Pivot hole (E) must face
the back of the sink.
C) Tighten locknut (C) and gasket but do not overtighten. Remove pivot ball retaining nut (E).
D) Slide pivot rod (F) into the eye of the pop-up plunger (A). Hand tighten retaining nut.
E) Slide pivot rod (F) through hole in spring clip (G), then through lever strap (H) and back
Silicone caulk
through spring clip.
F) Insert lift rod (I) down through faucet body and then into lever strap (H). Tighten screw (J).
Connect assembly to drain.
A
A
B
D
C
B
A
D
A
FLUSHING & AERATOR CLEANING
7
Remove the aerator by turning it counterclockwise with the plastic wrench provided. Remove the
internal parts of the aerator by pushing them out with your fingers. Remove any debris. Turn on hot
and cold water supplies. Turn faucet handles all the way on and run water through the spout for
about a minute to remove debris. While water is running check all connections for leaks. Reassemble
the aerator and screw it back into the spout hand tight.
EXPLODED DIAGRAM FOR REFERENCE
8
MAINTENANCE Your new faucet is designed for years of trouble-free performance. Keep it looking
new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh
chemicals as these will dull the finish and void your warranty.
1
2
15 - SPOUT
14 - AERATOR
13 - WRENCH
12 - SCREW
11 - BASE PLATE
10 - NUT
CUSTOMER SERVICE
WEST 1-800-267-4774 | EAST 1-800-387-7064 | taymor.com
FOR 3/8" O.D. BALL-NOSE SUPPLY TUBES
IF THE SUPPLY TUBE END HAS A BULBOUS SHAPE,
USE THE SUPPLIED COUPLING NUTS.
TORQUE
22 – 30 FT/LBS.
B
C
B
E
E
H
F
F
G
1 - HANDLE
2 - CLIP
3 - HANDLE SEAT
4 - BONNET
5 - CARTRIDGE
6 - WASHER
7 - WASHER
FLANGE
8 - ESCUTCHEON
9 - BODY
16 - POP-UP ASSEMBLY
® REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD.
E
C
F
I
J
H
LIFT ROD KNOB
LIFT ROD
LIFT STRAP
NUT
SPRING CLIP
PIVOT ROD
DRAIN

Publicité

loading

Sommaire des Matières pour Taymor DIXON 06-4308P

  • Page 1 WARNING: READ ALL the instructions completely before beginning. READ ALL warnings, care and maintenance information. Taymor recommends calling a professional if you are uncertain about installing this product! This product should be installed in accordance with all local and provincial plumbing and building codes.