Digital codelock module
ADHESIVE GASKET PLACEMENT
seal as shown in Fig. 2.
Apply the
Y
ANTI-TAMPERING LOCKS FIXING
Fit the anti-tampering locks
CONNECTION TERMINALS SIGNALS
SW2 Relay 2 command signal (active low)
SW1 Relay 1 command signal (active low)
NC3 Relay 3 normally closed contact
NO3 Relay 3 normally open contact
C3
Relay 3 common contact
NC2 Relay 2 normally closed contact
NO2 Relay 2 normally open contact
C2
Relay 2 common contact
NC1 Relay 1 normally closed contact
NO1 Relay 1 normally open contact
C1
Relay 1 common contact
12/24Vac/dc power input
+
Art. 4800 - Installation instructions
All manuals and user guides at all-guides.com
as shown in Fig. 3.
W
Max
24Vac/dc
3A
Y
G
Fig. 2
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.
TECHNICAL SPECIFICATION
Power Supply:
Power Consumption:
Working Temperature:
- 3 -
Fig. 3
12/24 Vac/dc – 2VA
Stand-by:
20mA
Operating:
70mA
-10 +50° C
66250070 - V2.1 - 30/06/18