PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE
IMPORTANT INSTALLATION INFORMATION
Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt, consult a qualified electrician.
Keep the LED Driver away from direct sources of heat such as Low Voltage lamps.
Ensure that ALL electrical connections are tight with no loose strands, including factory connections.
Indoor use only.
Constant Voltage drivers and parallel connections must be used.
INSTALLATION INSTRUCTIONS
Before commencing installation or maintenance, ensure electricity is switched off at the mains.
1.
A 12V DC LED Driver must be used with this strip.
2.
Ensure that the surface that the LED strip will be applied to is clean and free from grease
3.
Peel of the backing tape and fix the LED strip into the required position using the self-adhesive backing.
4.
The LED strip may be cut to length with cut points every 50mm.
5.
A maximum of 10m can be connected in one length. Runs over 10m must be connected in parallel. See Diagram 1 for connection details.
6.
Connect the LED Strips to the 12V DC Constant Voltage LED Driver and ensure that the polarity is correct. Also refer to the instructions provided with the
LED Driver
7.
Connect the Constant Voltage LED Driver to the mains supply.
8.
The LED strip will now be lit.
Diagram 1: Typical Installation with 50W Driver and 10m AU-ST100
240V ~ 50Hz
AU-LED5012CV
Constant Voltage
LED Driver
Environmental Protection (W.E.E.E.) – Aurora's WEEE Reg.No. WEE/BG0130YX
Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking (left) must not be disposed of
with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its customers for affected WEEE related products.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other
waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If,
when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his take
back of the product for the correct disposal.
WARRANTY
See www.auroralighting.com for full details of warranties and Extended Warranty Terms and Conditions. The warranty is invalid in the case of improper use,
tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National
Wiring Regulations. Should this product fail during the warranty period it will be replaced free of charge, this is subject to correct installation and return of the
faulty product. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the
statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.
Aurora Limited,
All manuals and user guides at all-guides.com
AU-ST100 - SINGLE COLOUR LED STRIP LIGHT
12V DC
12V DC
6 Little Burrow,
Burrowfields,
Welwyn Garden City,
Website: www.auroralighting.com
Document version – AU-ST100_V1_17_ENG&FRE.doc
AU-ST100
AU-ST100
10m maximum
In one length
AL7 4SW,
United Kingdom

Publicité

loading

Sommaire des Matières pour Aurora AU-ST100

  • Page 1 All manuals and user guides at all-guides.com AU-ST100 - SINGLE COLOUR LED STRIP LIGHT PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE IMPORTANT INSTALLATION INFORMATION Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt, consult a qualified electrician. • Keep the LED Driver away from direct sources of heat such as Low Voltage lamps. • Ensure that ALL electrical connections are tight with no loose strands, including factory connections. • Indoor use only. • Constant Voltage drivers and parallel connections must be used. • INSTALLATION INSTRUCTIONS Before commencing installation or maintenance, ensure electricity is switched off at the mains. A 12V DC LED Driver must be used with this strip. Ensure that the surface that the LED strip will be applied to is clean and free from grease Peel of the backing tape and fix the LED strip into the required position using the self-adhesive backing. The LED strip may be cut to length with cut points every 50mm. A maximum of 10m can be connected in one length. Runs over 10m must be connected in parallel. See Diagram 1 for connection details. Connect the LED Strips to the 12V DC Constant Voltage LED Driver and ensure that the polarity is correct. Also refer to the instructions provided with the LED Driver Connect the Constant Voltage LED Driver to the mains supply. The LED strip will now be lit. Diagram 1: Typical Installation with 50W Driver and 10m AU-ST100 12V DC 240V ~ 50Hz AU-LED5012CV AU-ST100 Constant Voltage LED Driver...
  • Page 2 All manuals and user guides at all-guides.com AU-ST100 - BANDEAU DE LED MONOCHROME VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION ET EN LAISSER UN EXEMPLAIRE À L’UTILISATEUR OU AU TECHNICIEN D’ENTRETIEN POUR RÉFÉRENCE INFORMATIONS D’INSTALLATION IMPORTANTES Cette installation doit être effectuée en conformité avec la dernière édition du Règlement national de câblage. En cas de doute, consultez un électricien • qualifié. Conservez le driver de LED à l’écart des sources directes de chaleur telles que des lampes basse tension. • Veillez à ce que TOUTES les connexions électriques soient bien serrées sans fils lâches, notamment au niveau des connexions d’usine. • Utilisation en intérieur uniquement. • Utilisez des drivers à tension constante et des branchements parallèles. • INSTRUCTIONS D'INSTALLATION Avant de commencer l'installation ou l'entretien, vérifiez que l'alimentation est coupée au niveau du secteur. Utilisez un driver de LED de 12V CC avec ce bandeau. Vérifiez que la surface sur laquelle sera appliqué le bandeau de LED soit propre et exempte de graisse. Retirez la bande de protection et fixez le bandeau de LED dans la position souhaitée à l'aide du dos autocollant. Vous pouvez couper le bandeau de LED à la longueur souhaitée, grâce aux points de découpe situés tous les 50 mm. Une longueur peut contenir un maximum de 10 m. Les sections supérieures à 10 m doivent être reliées en parallèle. Reportez-vous au schéma 1 pour obtenir les détails de connexion. Connectez les bandeaux de LED au driver de LED à tension constante 12V CC et veillez à ce que la polarité soit correcte. Reportez-vous également aux instructions fournies avec le driver de LED. Branchez le driver de LED à tension constante au secteur. Le bandeau de LED s'allume. Schéma 1 : Installation ordinaire avec driver 50W et AU-ST100 de 10 m 12V CC AU-LED5012CV 240V ~ 50Hz AU-ST100 Driver de LED à...