• HOLD/MAX
Press momentarily to hold the present value on the display. Press again to return to normal
mode.
To use the Maximum Hold function, press and hold before turning the unit on. Press again
to reset the stored maximum value. Press and hold for 2 seconds to return to normal
display. To remove the Maximum Hold function, turn the unit off and then back on.
• ZERO A
/Ω/
For DC current measurements, close the jaw around the conductor. Orient the jaw for a
positive reading for greatest accuracy. Remove the jaw from the conductor and close it.
Press the ZERO A
jaw over the conductor, keeping the same orientation, and take the reading.
For continuity measurements, press to enable tone. The
and the meter switches to the 400 Ω range. Press again to measure resistance.
• Auto Power Off Disable
Turn the selector to the OFF position. Press and hold the ZERO A
quickly turning the selector to the Ω/
selector is set to OFF or until the battery is depleted (approximately 150 hours for a fresh
alkaline battery).
The next time the unit is turned on, the 30-minute Auto Power Off will be enabled.