Accuracy (cont'd)
DC Current (21 °C to 26 °C)
Range
Input Value
0.0 to 40.0
400.0 A
40.0 to 200.0
200.0 to 400.0
600 A
400 to 600
DC Voltage (18 °C to 28 °C)
Range
± (0.7% + 0.2 mV)
400.0 mV
± (0.7% + 0.002 V)
4.000 V
± (0.7% + 0.02 V)
40.00 V
± (0.7% + 0.2 V)
400.0 V
± (0.7% + 2 V)
600 V
Resistance (18 °C to 28 °C)
Range
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
* Reading may have ripple up to 6 digits near full scale.
** Reading may have ripple up to 3 digits near full scale.
† Response time approximately 20 seconds.
Maximum Hold
Accuracy of held value is stated accuracy from table + 10 digits per range change.
For example, a 100 VDC spike on a 200 mVDC signal requires 3 range steps to measure.
The addition to the accuracy specification is 3 x 10 digits on the 400.0 volt range or 3.0 volts.
Note: Maximum hold accuracy for resistance is specified on 400.0 Ω to 400.0 k Ω ranges only.
All manuals and user guides at all-guides.com
Accuracy
Accuracy
± (1.2% + 0.6 Ω)*
± (0.9% + 0.003 kΩ)**
± (0.9% + 0.03 kΩ)**
± (1.2% + 0.3 kΩ)**
± (1.2% + 0.003 MΩ)**
± (2.5% + 0.05 MΩ)* †
Accuracy
± (1.5% + 1.0 A)
± (1.5% + 0.7 A)
± (2.5% + 0.7 A)
± (1.9% + 10 A)
Input Impedance
9 MΩ