Thin Wall
2x4
2-15/16" (75 mm) Min
1. Install the Support Framing
IMPORTANT! Make sure the valve is mounted at the correct depth
so it will be properly positioned when the finished wall is installed.
NOTE: Shower only configuration is shown. Adjust the support as
needed for other configurations.
NOTE: Install a backer board behind the valve for installations on
2x6 studding only.
NOTE: A backer board may not fit behind the valve for installations
on 2x4 studding. Support the pipes directly above and/or below the
valve. This will also provide support for the valve.
NOTE: When installing the K-2972 or K-2973 valve, use 1/2"
nominal copper tubing and fittings throughout this installation.
Smaller diameter piping upstream or downstream of the valve will
reduce performance of the valve.
1205551-2-D
Thick Wall
2x6
2-7/16"
(62 mm)
Finished
Wall
4-1/4" (108 mm) Max
10
3-3/4" (95 mm)
Plaster Guard
Finished Wall