TROUBLE SHOOTING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
GAS MODEL
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
[HUDSON]_Technical_information-03171A-01_EN.indd 9
WARNING
Gas Valve(25M01A)
Valve 1-2 : Resistance value about 1.2K Ω
Valve 1-3 : Resistance value about 0.5K Ω
Valve 4-5 : Resistance value about 1.2K Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat