Falltech C8150 Manuel De L'utilisateur page 8

Corde de secours verticale à ancrage unique et bloqueur de chute
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.4.3 FACSS Installation:
Step 1:
Attach the VLL to the anchor per Section 5.4.2.
Step 2:
To open the hinged arrester, hold it in your left hand. Rotate the safety latch all the way up. See Figure 8.
Step 3:
Unscrew the knurled locking knob. See Figure 9. Open the hinged gate. See Figure 10.
Figure 8
Step 4:
Lift the ring to retract the cam assembly. See Figure 11. Place the VLL in the rope channel. See Figure 12.
Step 5:
Close the gate. The arrester utilizes an anti-inversion cam in the hinge to prevent the grab from closing if incorrectly oriented.
The arrow must point up to close.
Step 6:
Screw the lock knob back in until tight. See Figure 13. Rotate the safety latch all the way down. See Figure 14.
Step 7:
Connect the EAL to the Arrester (if applicable).
Step 8:
Connect the EAL shock-absorbing end to the FBH dorsal or stenal D-ring.
CMVLL01 Rev A
Figure 9
Figure 11
Figure 13
041020
Figure 10
Figure 12
Figure 14
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C8200C8388

Table des Matières