12.4 SPÉCIFICATIONS GÉNÉRALES
(1) Class of Emission
(2) Display
(3)Display capability
(4) Screen
(5) Range Scale
(6) Range Resolution
(7) Minimum Detective Range
(8) Range Accuracy
(9) Bearing Accuracy
(10) Bearing Indication
(11) Ambient Condition
Standards
Temperature
Scanner
Other Unit except Scanner Operation: -15 to +55°C / Storage: -15 to +70°C
Relative Humidity
Vibration
Velocity of the wind
Waterproof/dustproof
(12) Power Supply Input
(13) Power Consumption
(14) Pre heat time
(15) Display unit
(16)Inter-unit Cables
Chapter 10 SERVICE APRÈS-VENTE
P0N
Color Raster Scan
WVGA (800x480dots) Screen
7-inch Color LCD with touch sensor (resistance film type)
0.0625, 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48NM
(48 NM: only 2feet type scanner is available)
User can add 1, 2, 4, 8, 16, and 32NM
(32 NM: only 2feet type scanner is available)
Less than 30m
Less than 40m
Less than 1% of the maximum distance of the range scale
in use or less than 15m whichever is larger.
Less than ±1°
RM: Head-up, North-up, Course-up
TM: North-up, Course-up
IEC60945 Ed.4.0
Operation: -25 to +55°C / Storage: -25 to +70°C
+40°C, 93%
2 to 13.2 Hz, amplitude±1mm
13.2 to 100 Hz, 0.7 G
100kn
Scanner
IP26
Display unit
IP55
DC 10.8-31.2V (DC12-24V-10%+30%)
Approx. 50W (NKE-1066/NKE-2044).
Maximum: 50W
(NKE-1066: SP1, NKE-2044: LP2 transmitting)
Approx. within 1min30sec.
Refer to Display unit Specifications
Using common scanner connecting cable CFQ9924-10
Standard Length 10m
Maximum cable length 30m (option)
139

Publicité

loading

Ce manuel est également adapté pour:

Jma-1032Jma-1034