Télécharger Imprimer la page

ATH-Heinl Single Lift 12PL Manuel D'utilisation page 54

Publicité

Les langues disponibles

Les langues disponibles

Safety devices
1. Control box from the column equipped with Deadman's Type Controls
Includes the complete electrical control system. All the push buttons are protected by a front ring and the
operator is required to hold the controls in the engaged position to rise or lower the lift in case of releasing
operation is immediately interrupted.
2. Locking safety notch
This safety device prevents by any deficiency a lowering of the carriage by more than 100mm.
The electromagnets unlock the device every time, when the lowering and lifting are carried out.
Position by locked (parked) carriage:
3. Main Switch
4. Foot Protection
5. Pressure control valve,
Prevents the exceeding of the payload. Verhindert ein Überschreiten der Traglast.
THIS SETTING MAY NOT BE CHANGED!
6. Emergency descent screw,
makes possible a lowering of the carriages of the lift by defective working.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2022-02
Manufacturer ATH-Heinl GmbH & CO.KG
- 5 -
Position by unlocked carriage: