LED
Green
rot
Orange
(1)
(2)
(3)
Potential-free contact is activated (Art.No. 80074 must have been activated and connected beforehand)
1
The battery monitoring is only active if a battery was connected at the time of commissioning.
2
Alarm statuses / errors
LED
Green
rot
Orange
(1)
(2)
(3)
38 / 128
Acoustic
signal
PFC
orange
(interval)
(4)/(5)
-
-
-
-
Acoustic
signal
PFC
orange
(interval)
(4)/(5)
Yes
Yes
Yes
Yes
Installation and operating instructions
Description
1
System tank full, will
be pumped out shortly
Pumping sys-
tem tank to empty
Description
1
Battery error
2
Power outage, mains voltage
failed, system non-functional
Level error, illogical
sequence of levels detected
Max. number of runs/run-
time; wastewater pump was
switched on too often/too long
Measure
No action required, waste-
water pump can be switched
off with button (8) (see "Man-
ual operation", page 35)
Measure
Replace battery
Reinstate mains volt-
age, acknowledge alarm
Acknowledge alarm
3
016-207_02