2.10 Completion of Work
Before commissioning, check all fastening screws, electrical, pneumatic and hydraulic
lines and, if necessary, tighten these. Warning: in some cases, this must be checked at
regular intervals and tightened if necessary (note in the instructions).
Adjustment of the top end-limit switch
Raise the lift at a height of 1870 mm to check for the proper position.
If the switch does not function properly, unloosen its lever and adjust it at a proper position until the lift
can reach at the desired height.
Tighten the screw after adjustment.
Adjustment of the CE-limit switch
Place the lift at a height of 200 mm
If the switch does not function properly, unloosen its lever and adjust it at a proper height (it is suggested
to be lower 1-3mm than the cross beam).
Tighten the screw after adjustment.