TROUBLESHOOTING (cont.)
Visible External
Monitoring / Test
Indication LED (red)does
not flash.
Visible External
Monitoring / Test
Indication LED (red)
flashes continuously
Door cycles open and
remains open
• IXIO sensors are intended to be used with pedestrian sliding door systems.
• This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the
instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
TECHNICAL SPECIFICATIONS (SENSOR)
Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Applicable directives:
Detection mode:
Technology:
Output:
Test/Monitoring
input:
Norm conformity:
Page 8 of 9
Monitoring installation/set-
up error.
Sensor and/or wiring
malfunction.
Wiring issue
Control not set correctly
Door control monitoring set
to Active High.
12 – 24 VAC ±10%
12 – 30 VDC ±10%
< 2.5 W
6'6" – 11'6"
Sensor: -13 – 131 °F *
0 – 95% relative humidity, non-condensing
IP54
< 70 dB
R&TTE 1999/5/EC
MD 2006/42/EC
MOTION
minimum detection speed: 2 in/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
Electro-mechanical-relay
(potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VDC
Adjustable Holdtime: 0.5 – 9 s
Verify door control is capable of monitoring and the
sensor monitoring wires are properly connected to
the door control.
Verify monitoring (TEST) is on in the sensor settings.
Verify that there are no breaks anywhere in the
wire harness.
Replace the sensor.
Verify wiring.
Verify control monitoring set to Active Low.
Set door control moitoring to Active Low.
to be operated from SELV-compatible power supplies only
local regulations may impact acceptable mounting height
LCD screen is operational from 14 – 131 °F.
The sensor may still be programmed in colder
temperatures, but with the remote control.
LVD 2006/95/EC
ROHS 2 2011/65/EU
PRESENSE
typical response time: < 200 ms (max: 500 ms)
Active infrared with background analysis
Spot: 2" x 2" (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
2
Solid-state-relay
(potential and polarity free)
Max. contact current: 400 mA
Max. contact voltage: 42 VAC / VDC
Holdtime: 0.3 – 1 s
Sensitivity:
Low: < 1 V
High: > 10 V (max. 30 V)
Response time on test request: typical < 5 ms
EN 12978
EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system monitors
the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1
see following page for camera specifications