Adjust detection distance:
• Cancel the "sleep" mode if this has not already been done.
• Activate "settings mode": (see procedure "Activate settings mode"), unless the settings mode
has already been activated and you haven't cancelled it (with a conventional detection).
• Press and hold the settings button  (Fig. J) until the LED  (Fig. I) blinks quickly.
• Place your other hand at the required distance from the sensor  (Fig. J) (between 5 and 15cm).
• Release the button, the LED  (Fig. I) will stay lit for up to 2 seconds.
• Remove hand from beneath the sensor.
Setting the detection distance is complete.
• Check the new distance meets your requirements. If necessary repeat the procedure to achieve
the correct distance.
Adjusting dispensed volume:
• Activate "settings mode": (see procedure "Activate settings mode"), unless the settings mode
has already been activated and you haven't cancelled it (with a conventional detection).
• Press the settings button twice  (Fig. J): the LED  (Fig. I) will blink slowly (for 5 seconds).
• Durings these 5 seconds, place hand beneath the sensor  (Fig. J): several doses (1.6ml default)
are dispensed consecutively. Remove hand when the desired quantity is reached (7 doses maximum).
The new quantity will be registered and dispensed for all future uses.
The adjustment of the dispensed volume is complete.
MAINTENANCE
The dispenser has not been used for a prolonged period of time:
• Press the settings button 8 times consecutively  (Fig. J), to activate pump's priming mode
(which will turn continuously in the opposite direction).
• Let it turn for about 5 seconds, and press the settings button once again  (Fig. J) (the pump will stop,
and return to dispensing mode).
• Run through a few detections to re-prime the pump.
• If at the end of 10 detections, the soap is still not being dispensed, check that the dispenser does
contain soap:
- If not, fill the tank, and try detection again.
- If yes, either the pump or the nozzle are blocked. The nozzle can easily be unblocked with a Ø 2mm
(max.) long object, inserted up to 10mm in the nozzle (further could risk damaging the pump).
The LED  (Fig. I) is blinking continuously:
• Open the lid (Fig. H) to access the electronic unit.
• Open the hatch  (Fig. F).
• Remove the battery case.
• Remove the battery holder from its protection case.
• Change the 6 AA batteries (do not mix new and used).
• Put the battery holder back in its protection case.
• Put the case back in place, and put the wires back carefully.
• Close the hatch  then the lid (Fig. F and H).