OPERATION (Fig. I & J)
The electronic dispenser is compatible with vegetable-based liquid soap with a maximum viscosity
of 3,000 mPa.s and hydroalcoholic gel.
When using hydroalcoholic gel in the dispenser, always replace the tank cover properly after
filling to avoid rapid evaporation and potentially flammable vapour emissions.
Our mechanisms work with World Health Organistion (WHO) recommended hydroalcoholic
solutions composed of the following: ethanol, 3% hydrogen peroxide, glycerol, purified water.
Any other additives can cause the pump to malfunction, requiring more frequent maintenance.
• The batteries supplied with the product are demonstration batteries to prevent damage
to the aspiration system.
• The mechanism opens and closes automatically when the hands are detected by the infrared sensor.
• Before first use, deactivate the "sleep" mode (rotation of the pump every 72hrs to prevent damage
to the silicone tube): press the settings button  for 5 seconds (Fig. J).
The LED  (Fig. I) will light up for 3 seconds.
• To reactivate the "sleep" mode: press the settings button 5 times consecutively , the LED 
will light up for 3 seconds. (For safety, you can check that the product is no longer detecting).
INSTALLATION
• Install the dispenser at least 250mm above the basin (350mm if it's a stainless steel basin).
• In order to avoid interference from infrared waves, do not install reflective objects within the sensor's
field of detection  (Fig. J).
• Power supplied by 6 AA – 1.5 V (DC9V) batteries, supplied in the case.
• Remove the cover  (Fig. G). Fill the tank with liquid soap with a maximum viscosity of 3,000 mPa.s.
• Replace the cover  on the tank, and close the lid (Fig. H). The LED  (Fig. I) will blink 5 times.
REMEMBER
• Our products must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Do not shake the dispenser.
• Do not block the soap outlet or the sensor.
SETTINGS
Factory settings:
• Detection distance: 100mm.
• Dispensed volume: 2 doses of 0.8ml, i.e. 1.6ml.
Activate settings mode:
• Open the lid (Fig. G), to cut off the dispenser supply.
• Wait at least 5 seconds and then close lid, without carrying out any other action (detection, pressing
the settings button etc.). The LED will blink 5 times.
• The settings mode is now available until normal use is detected.
• See sections opposite for different settings.
EN