Installation - Dyna-Glo Pro EG7500DGP Instructions D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MOUNTING THE BRACKET
Refer to Figures 4a and 4b.
1. Locate a wood stud in the wood ceiling joist/side wall. For ceiling only, if you
cannot locate a wood stud, you have to install a wood piece on the ceiling as
this heater must be securely fastened.
2. Remove the mounting bracket from the heating unit by loosening bracket
screws with a wrench and slipping the handle off over the screw heads.
3. Place a washer on screws before inserting through the holes in the mounting
bracket and screw them securely into a ceiling joist or wall stud.
NOTE: If you want to swivel the heater either to the right or left adding a washer
to both sides of the bracket is recommended. A longer lag bolt may be required
to properly secure the unit. See Figure 4a.
Wood Ceiling
Figure 4a. Single-Screw Mounting
HANGING THE HEATER
1. Attach the heating unit to the mounting bracket.
2. Lift the heater up and into the mounting
bracket.
3. Align the bracket screws with the keyhole slots
in the mounting bracket.
4. Tighten the bracket screws with a wrench so
the unit is securely suspended at horizontal or
vertical level.
5. The heater can be mounted with different
angles listed in the drawing on page 7 as long
as you maintain proper clearance listed on
page 4.
ADJUSTING AIR FLOW DIRECTION
1. To turn the unit when it has been installed
with a single lag bolt (as shown in figure
4a), simply turn the entire heater as needed.
The unit cannot be turned horizontally if it
has been installed with 2 lag bolts.
2. To tilt the unit vertically, loosen the bracket
screws (see figure 5).

INSTALLATION

LOOSEN KNOBS AND SELECT MOUNTING
HOLE BASED ON DESIRED HEATER ANGLE.
REFER TO DIAGRAM ON PAGE 7.
Wood Ceiling
Figure 4b. Double-Screw Mounting
Figure 5