Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal pressu-
res.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
6
English

Symbol description

max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 ±12mm
cold right - hot left
Assembly see page 8
To adjust the hot water limiter on single lever
mixers, please see page 12. No adjustment
is necessary when using a continuous flow
water heater.
Maintenance (see page 14)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Do not use silicone containing acetic acid!
Dimensions (see page 10)

Flow diagram

(see page 10)
with EcoSmart®
without EcoSmart®
Spare parts (see page 11)
Operation (see page 13)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning
see enclosed brochure.
Test certificate (see page 16)