Thomas CentraClean 15-301 Mode D'emploi page 25

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
5.2.
Planning the standard, floor and premium suction boxes
5.2.1 Suction box overview
Control system
Premium
KU
Radio
X
Control cable
X
5.2.2 Planning Standard suction box
without mounting frame
– Insert siphon knee as connection piece to the suction box and fix
with plaster
– Siphon knee always under the plaster (minimum wall thickness
11 cm), and lay flush with the wall surface (including plaster and
wallpaper).
– Note:
The wall covering must be precisely in line with the siphon knee
without joint.
Middle of suction box is not the middle of the siphon knee
5.2.3 Planning floor suction box
– Note:
– Insert the 90° bend DN 50 (including
reducing piece supplied in the extent
of the delivery) into the suction box
– Chisel out and remove the screed in
the region of the suction box
Suction boxes
Standard
Floor
suction
suction box
KF
MU
box
X
X
X
X
82 mm
X
X
11 cm
3 cm
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Centraclean 18-451Centraclean 34-451Centraclean 451 za

Table des Matières