Steelcase Alimentation modulaire universelle Directives D'assemblage page 13

Table des Matières

Publicité

®
1. Place the block with the infeed connector port facing
the direction of the power outlet that will power the system.
2. For Standard Application
a) Screw the distribution blocks onto the underside of the desks.
The blocks must be located 7"/180mm from the perimeter.
NOTE: location of the distribution blocks (grey) should be based off
the central location of the user power it will connect.
For Use with Universal Cable Tray
b) Attach the distribution block to the distribution block adapter with provided
fasteners. Slide the distribution block adapter into the tray's t-slots.
3. Connect each desk to one another by installing the jumper cords to the
infeed/jumper ports of the distribution blocks.
Press until tabs lock into place.
3
Fixed Height Desks
1
Infeed Port
User Power
Port
2a
2b
9.5mm
3/8"
2x
Doc # 160136 Rev C
19mm
7/8"
2x
Page 13 of 23