30 "(inches) (760mm) is the minimum vertical distance to combustible material above the cooktop. This
distance may be reduced by using non-combustible construction in accordance with table 5.6.6.5
Vertical Clearances to Combustible Material or Metal Cabinets in NFPA1192:2021.
Provide an air gap of at least 1
Maintain provision for the dispersal of unburnt gas, for example a gas drop hole.
Provide a ventilation gap of
Protect the underside of the appliance with a shield, made from non-combustible material, if the space
below the hob is used for storage or another appliance.
If the enclosure is manufactured from combustible material, then a minimum air space of 100mm must
exist between the material and the lowest part of the appliance.
THIS AIR SPACE MUST BE WELL VENTILATED
Ventilation
Use of a gas cooking appliance results in the production of heat and moisture in a room in which it is
installed. Ensure that the kitchen is well ventilated and in accordance with local and state codes.
Gas cooking appliances needs fresh air for safe operation.
Before operating open vents, or windows slightly, or turn on exhaust fan prior to using the cooking
appliance. Gas flames consume oxygen, which should be replaced to ensure proper combustion.
Improper user can result in serious injury or DEATH.
DO NOT obstruct the flow of combustion or ventilation air.
The appliance SHOULD have adequate ventilation for complete combustion of gas, proper flueing
and to maintain temperature of immediate surroundings within safe limits.
The appliance SHOULD NOT be installed with a ventilation system that blows air downward toward
the range. Downward ventilation systems may cause ignition and combustion problems with the gas
cooking appliance resulting in personal injury or unintended operation.
Adherence to national standards regarding ventilation for the recreational vehicles into which the
appliance is to be installed is a MUST.
3
/
" (30mm) under the unit (A), using non-combustible material
8
5
5
/
" x 3
/
" (8x100mm) (B)
16
16
15