ELECTRICAL CONNECTION

• It is mandatory to use a power point with a ground terminal, connected in accordance with
current safety regulations.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
• The installation of this appliance and the connection to the electrical system should be
entrusted only to a qualified electrician.
• Protection against the parts under tension must be ensured after instalation
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the mains must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 1 Phase + N 50/60Hz
400V~ 2 Phases + N 50/60Hz
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L1 to the terminals 1
and the Phase L2 to the terminal 2.
Caution! Ensure that you correctly attach the wires and the bridges and tighten the screws
properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Cable diameter
3 x 2,5 mm²
4 x 1.5 mm²
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
40
Protection calibre
25 A *
16 A *