Télécharger Imprimer la page

ims PRO TIG TITANIUM 400 AC/DC Mode D'emploi page 41

Masquer les pouces Voir aussi pour TIG TITANIUM 400 AC/DC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
• Foot pedal (option ref. 045682) :
The pedal control enables variation of the current from the minimum current to 100% of the set intensity.
In TIG, the welding machine only operates in 2T mode. The upslope and downslope are not automatically managed by the current source, and are
controlled by the user with the foot pedal.
The digital remote control allows to connect a remote HMI or a TIG dispenser.
COOLING FAN
To minimise sound and dust aspiration, the station integrates a controlled fan system. The fan's rotation speed depends on the temperature and the
machine's settings.
ENERGY MODE
This mode developed for welding with energy control framed by a DMOS allows, in addition to the energy display of the bead after welding, to set:
- The thermal coefficient according to the standard used: 1 for ASME standards and 0.6 (TIG) or 0.8 (MMA) for European standards. The energy
displayed is calculated taking this coefficient into account.
- The length of the weld seam (OFF - mm): if a length is recorded, then the energy display is no longer in joule, but in joule / mm (the unit on the
display «J» flashes).
COOLING UNIT
WCU1kW_C
The cooling unit is automatically detected by the machine. In the «Settings» menu / Cooling unit: the cooling unit can be disabled.
The protections supported by the cooling unit to ensure the protection of the torch and the user are:
• Minimum coolant level.
• Minimum flow rate of coolant flowing through the torch.
• Thermal protection of the coolant.
Make sure that the cooling unit is turned off before disconnecting the inlet and outlet hoses for torch liquid.
The coolant is harmful and irritates the eyes, the mucous membranes and the skin. Hot liquid may cause burns.
PRODUCT CONFIGURATION
INFORMATION
This menu provides access to the version numbers of the cards and software.
IMS TIG TITANIUM 400 AC/DC
P 1L/min = 1000 W
Capacity = 5 L
U1 = 400 V +/- 15%
The cooling unit is controlled in 400 V +/-15%.
EN
41

Publicité

loading