Tool registration for the adaptor
To register a tool to the adaptor (wireless unit), follow
the instructions in the instruction manual of the tool to
be used with this adaptor. Refer to the section about
"tool registration".
NOTE: In the tool's instruction manual, follow the
instructions by substituting the wireless activation but-
ton/lamp "on the vacuum cleaner" with "on the adaptor".
NOTE: Make sure that the wireless unit is installed to
the adaptor and the adaptor is plugged into the outlet
of the vacuum cleaner before starting tool registration.
NOTE: The tool registration information is saved to
the wireless unit inserted to the adaptor. You can use a
pair of wireless units, of which the tool registration has
been finished, with another tool and vacuum cleaner.

Channel setting

The suitable communication channel varies depending
on the vacuum cleaner to be used with the adaptor.
Perform the channel setting when;
Using the adaptor for the first time or;
Using another vacuum cleaner which have not
been used with the adaptor.
NOTE: The last channel that you set will be saved
even after you unplug the adaptor.
1.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
► Fig.6: 1. Stand-by switch
NOTE: On some cleaners, the stand-by switch
"AUTO" is described as an icon or different word. In
this case, set the vacuum cleaner to auto start/stop
function.
2.
Confirm the number beside the lighted channel
number indicator. It is the channel number currently
being selected.
► Fig.7: 1. Channel setting button 2. Channel number
indicator
3.
Push and hold the channel setting button for lon-
ger than 2 seconds for testing.
The channel number indicator will blink in green for 15
seconds.
► Fig.8: 1. Holding the channel setting button (2 sec-
onds or longer) 2. Channel number indicator
blinks (for 15 seconds) 3. Vacuum cleaner
runs while the channel number indicator is
blinking
4.
Check if the vacuum cleaner automatically runs
correctly while the channel number indicator is blinking.
If so, the channel setting is completed.
If the vacuum cleaner does not run or run incorrectly, go
on to the next step.
NOTE: For example, when the vacuum cleaner runs
incorrectly; the vacuum cleaner runs but stops soon
or; the level of the suction power is different from the
setting on the vacuum cleaner.
5.
Push the channel setting button briefly to select
another channel number.
6.
Hold the channel setting button for longer than 2
seconds for testing and check if the vacuum cleaner
runs correctly.
If not, repeat the step 5 to 6 again.
If the vacuum cleaner does not run in any of the channel
number, the vacuum cleaner may not be supported or
there may be a problem in the configuration.
OPERATION
For the following operations, refer to the instruction
manual of the tool to be used with this adaptor:
Starting the wireless activation function
Cancelling tool registration
NOTE: In the tool's instruction manual, follow the
instructions by substituting the wireless activation
button/lamp "on the vacuum cleaner" with "on the
adaptor".
NOTE: Before performing the above operations, be
sure to;
Install the wireless unit to the adaptor and;
Plug the adaptor into the outlet of the vacuum
cleaner with the stand-by switch on the vacuum
cleaner "O (OFF)".
NOTE: The wireless transmission distance varies
depending on the vacuum cleaner model to be used.
Erasing all tool registrations
You can erase all tool registrations from the adaptor
(wireless unit) as follows.
1.
Make sure that the stand-by switch on the vacuum
cleaner is set to "O (OFF)" and then plug the vacuum
cleaner's power cord into the mains.
2.
Install the wireless units to the adaptor.
3.
Plug the adaptor's cord into the cleaner's outlet.
4.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
NOTE: On some cleaners, the stand-by switch
"AUTO" is described as an icon or different word. In
this case, set the vacuum cleaner to auto start/stop
function.
5.
Hold down the wireless activation button on the
adaptor for about 6 seconds until the wireless activation
lamp blinks in red (about twice per one second).
6.
When the wireless activation lamp starts blinking
in red, release your finger from the wireless activation
button. Thereafter, hold down the wireless activation
button again for about 6 seconds.
7.
When the wireless activation lamp starts blinking
fast (about 5 times per one second) in red, release your
finger from the wireless activation button. When the
wireless activation lamp lights up in red and later lights
off, all tool registrations are erased.
NOTE: If the wireless activation lamp does not blink
in red, press the wireless activation button briefly and
try again.