INSTALLATION
Wiring
For Power Sharing, the chargers communicate through a daisy-chain cabling system. When
connecting three or more chargers, the first and last chargers of the chain will be Terminating
(T) chargers and the chargers in between will be Non-terminating (NT) chargers as shown in
the figure below. (Note: when connecting only two chargers, both will be Terminating.)
Installation
Draw the communication cables between the chargers through the selected conduit (see
Preparing the Chargers section above) as shown below. Ensure that the total length of the cable
is no more than 820 feet (~250m)
The cabling consists of a daisy chain of a pair of wires connecting the chargers: a CAN-low
(CAN-L) wire and a CAN-high (CAN-H) wire.
We recommend to use the following cable-type: Ethernet Class 5E unshield, 1 pair.
T
T
T
NT
NT
CAN-L
CAN-L
CAN-H
CAN-H
NT
NT
NT
NT
The cabling polarity must always be respected:
CAN-H must be connected to CAN-H terminal.
CAN-L must be connected to CAN-L terminal.
T
T
9