Télécharger Imprimer la page

Desoutter ESP2-A Mode D'emploi page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
English
Speed (% of the
tool maximum
Sp
speed)
Running time
T
Tightening phase
Speed
Sp
Minimum
Tm
tightening time
Maximum
TM
tightening time
When the tightening phase stops before "Tm" or
after "TM", the report is NOK and the sound is
emitted by the controller.
Turbo phase
This phase is not compatible with the "Slow start"
phase.
Running time at
TT
L0 speed
Post-run reverse
This phase can be programmed after the
tightening phase.
This phase is not compatible with the "Pre-run
reverse" phase.
Speed (% of the
tool maximum
Sp
speed)
04/2022
L0
100%
L1 ~ L9
30% ~ 90%
Set "T" to "0" to
disable the function.
0.0 to 9.9 seconds.
L0
100%
L1 ~ L9
30% ~ 90%
From 0.0 to 9.9 second
From 0.0 to 9.9 second
Tmax-0.2 sec. by
default.
From 0.0 to 9.9 sec.
L0
100%
L1 ~ L9
30% ~ 90%
Running time
Batch count
The number of screws for this Pset can be set
from 1 to 99.
Automatic learn
When the screwdriver is running under
"Automatic learning mode", the controller records
the time between the trigger pressing and the
clutch.
Save the programming
Press this key to return to the
"Sub-menu".
The "X" is blinking.
Press this key again for 3 seconds until
the buzzer sounds.
The "X" is steady. The programming is saved.
● Turn the keylock to the right to protect the
programming against hazardous changes.
How to restore default values
Press this key during 5 seconds to
restore default values.
Trouble-shooting
Code Description
E1
No tool connected
No tool is enabled
or both tools are
enabled.
15 / 174
6159922220_06
Set "T" to "0" to
disable the function.
T
0.0 to 9.9 seconds
Solution
Connect tool A
or B.
Check the
tool and PLC
connections.

Publicité

loading

Ce manuel est également adapté pour:

6159327080