OPERATION
Controls (Fig.1)
The hood is operated using the (5) push buttons located on the front edge of the hood.
Filter Alarm
Indicator
Filter Alarm /
Timer Reset
Speed
Indicators
Blower
On / Speed
Blower
Off / Speed
Light On
Light Off
Filter Alarm
After 30 hours of blower operation, the filter alarm is activated and Filter Alarm Indicator
LED turns red. It indicates the grease filters need to be cleaned.
After 120 hours of blower operation, the filter alarm is activated and Filter Alarm Indicator
LED turns red and flashes. It indicates the grease filters need to be cleaned and the
charcoal filters need to be replaced (for non-ducted applications).
After cleaning the grease filters (and/or replacing the charcoal filters), reset the hour counter
by pressing the Filter Alarm / Timer Rest button during display of the alarm.
Auto Shut-Off Feature
If the blower and/or the lights are on continuously for 10 hours without any user interaction
with the controls, the hood will automatically shut off. Press any control button to re-activate
the hood.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that
will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF.
When this occurs, it is impossible to turn the blower OFF with its switch. If you must
stop the blower, do it from the main electrical panel.
When LED is red (motor off) it indicates the
filter alarm. When LED is green flashing, it
indicates timer is activated and Filter Alarm
/ Timer Reset button has been pressed.
When pressing the button during the dis-
play of the filter alarm (blower off) it resets
the filter alarm. When pressing the button
while the blower is on, it activates the ten-
minute timer function and the blower will
automatically turn off in ten minutes.
The green LEDs indicate blower speed.
Activates the blower (at the last speed
used) and increases the blower speed until
the maximum speed is achieved.
Decreases the blower speed. If pressed for
two seconds, the blower will turn off.
Turns lights on
Turns lights off