Télécharger Imprimer la page

Technical Specifications - NVT Phybridge FLEX24-10G Guide D'installation Rapide

Publicité

Quick Install Guide - FL E X2 4 -1 0 G
System Grounding (Earthing)
General grounding
GROUND ALL SYSTEMS ACCORDING TO THESE INSTRUCTIONS BEFORE YOU CONNECT POWER LEADS.
FOLLOW INSTRUCTIONS EXPLICITLY TO ENSURE THE SAFETY OF PERSONNEL.
Cabinets always require redundant and independent equipment grounding conductors between the cabinet and the wiring system ground: an insulated grounding
conductor and a supplementary (protective) ground.
Grounding conductor
The grounding conductor is provided as part of the three-wire, 15-Amp, AC-power cord set included with the equipment. If the power cord must be replaced, use a
power cord of the same gauge that has the same insulation, number of conductors, and usage ratings.
Protective grounding conductor
Install the protective grounding conductor to the system.
The ground symbol within a circle identifies the terminal to be connected to an external protective conductor. Connect this terminal to earth
ground before you make any other connections to the equipment. The protective grounding conductor must be:
• An Insulated wire, #5 (13mm2) to #14 (2mm2) AWG, with green and yellow stripes
• Connected to the grounding stud on the back of the cabinet.
Technical Specifications
Model
Part Number
Dimensions
Weight
Mounting
Processor
Interface:
Ethernet Uplink
Interface:
Downlink (PoE and IP to Adapter)
Management
Power Supply
Power Output
Power Consumption
Power Injection (PoE)
PowerWISE
Power Sharing
®
Operating Temperature
Humidity
Specifications subject to change without notice.
888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com
FLEX24-10G
NV-FLX-024-10G
19 inches x 1U without rack ears: (HxWxD) 1.73" x 17.13" x 10.45"
(4.39cm x 43.51cm x 26.54cm)
7.35lb (3.33kg)
Standalone or rack or shelf-mountable 2 brackets included for installation
MIPS32 24KEc, 500MHz
Maximum 2 uplinks, each 10 Gb/s (full duplex):
2 SFP+ ports: 1000 Base-T/TX/SX/LX/EX/ZX, 10GBase-CU/SR/LR/ER/ZR (determined by SFP or SFP+
transceiver module installed), Ethernet IEEE 802.3z, fiber optic cable/UTP
24 x RJ45 Jacks
Speed: 10/100/1000Mb/s (full duplex)
PoE Power: 50 Watts Maximum per port
Maximum Distance:
Mode
Cable
Standard
CAT5e or better
Long Reach Ethernet:
Mode
Cable
Long Reach
1 - 4 pairs UTP
1 LAN port (MGMT): RJ45 10/100/1000 base-T autosensing, IEEE 802.3
1 RS-232 console port: RJ45 to DB9 cable
Hot-Swappable Power Supply Unit
Autosensing 100-240VAC, 50 / 60 Hz
1000W max at 100VAC
1000W max at 240VAC
20W
DC Voltage: 48VDC to 58VDC
IEEE 802.3af/at
2 male connectors (rear), DC IN and DC OUT: 48VDC to 58VDC
14°F to 113°F (-10°C to +45°C)
10% to 95% (non-condensing) at 35°C (95°F)
Data Rate
Reach
10/100/1000Mbps
328ft (100m)
Data Rate
Reach
10/100Mbps
2,000ft (610m)
Copyright 2020 NVT Phybridge | 445-0030 REV. B | Page 6