Ensure gas supply and gas-type as shown on unit data plate agree.
Installation of this equipment must conform to the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National
Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit by
turning the adjustment screw at the bottom of each leg. Do not slide the unit with legs mounted; lift, if necessary, to move
the unit.
Use the correct pipe thread compound on any threaded pipe connections. It must be resistant to the action of liquified petroleum gases.
To avoid property damage or personal injury, DO NOT use an open flame to check for leaks. Check all
gas piping for leaks with a soap and water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES AND NEAR NON-COMBUSTIBLE WALLS ONLY.
Noncombustible clearances:
6" sides (152 mm)
6" rear (152 mm)
4" floor (102 mm)
Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue.
Adequate clearance for air openings into the combustion chamber is required. Do not store anything under the unit.
Do not permit air to blow directly at the unit. Wherever possible, avoid open windows next to the unit's sides or
back. Avoid wall-type fans which create air cross-currents within a room.
Sufficient make-up air should be allowed to enter the room to compensate for the ventilation system. Otherwise, a
negative atmospheric pressure will occur and can cause intermittent operation.
A properly designed and installed hood and ventilation system is required for correct installation.
Do not permit air to blow directly at the unit. Wherever possible, avoid open windows next to the unit's sides or
back. Avoid wall-type fans which create air cross-currents within a room.
Sufficient make-up air should be allowed to enter the room to compensate for the ventilation system. Otherwise, a
negative atmospheric pressure will occur and can cause intermittent operation.
A properly designed and installed hood and ventilation system is required for correct installation.
To avoid risk of product or property damage or personal injury, installer must verify the installation
complies with the applicable local codes and regulations. The unit must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts.
TO AVOID RISK OF PRODUCT OR PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, INSTALLATION OF
:
THE CHAR BROILER MUST BE PERFORMED BY PERSONNEL QUALIFIED TO WORK WITH GAS.
TO AVOID RISK OF PRODUCT OR PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, THIS UNIT IS
:
FOR COMMERCIAL USE ONLY. NEVER USE RESIDENTIAL GRADE GAS CONNECTIONS. RESIDENTAL
CONNECTIONS DO NOT MEET GAS CODES AND COULD BE HAZARDOUS.