detector channel whose attributes you want to change. To select
the detector channel, press SELECT.
Note: Detector channels 1-4 affect the function of relay output
1, whilst detector channels 5-8 affect the function of relay
output 2.
Confirm the selection of the detector channel by pressing SET.
The LED of the selected detector channel flashes or lights up.
To change the attribute of the detector channel, press
SELECT. A constantly lit LED means that this output is
programmed as a permanent contact. A flashing LED means
that this output is programmed as a pulse contact.
After setting the attribute of the detector channel, confirm the
selection by pressing SET. You now return to the detector
channels selection menu.
After
making
programming mode by pressing ESC/DEL.
The LED for the power supply lights up/flashes and the fault LED
lights up. The accessory module beeps at short intervals.
Close both tamper contacts of the WAM and wait until it emits
a double tone.
If the channel is programmed as a permanent contact, activate
the output by pressing button 4 (square) and deactivate it by
pressing button 3 (hash). If more than one remote control was
trained, then the deactivation command must be received from
every remote control in order to deactivate the output.
6.3.7

Wireless cylinder receiver

Function 7 / LED 7
When used as a wireless cylinder receiver, a connected system
can also be activated and deactivated with the wireless cylinder using
the accessory module. The accessory module works as a block lock.
There are two modes here. In mode one, two cylinders control a
relay. In mode two, four cylinders control a relay.
To use the accessory module as a wireless cylinder receiver,
proceed as follows:
1. Set the position of dip switch 1 to ON and all others to OFF. More
information on the position of dip switch 8 can be seen below.
In the main programming menu, select item 7 (Function). LED 7
lights up.
Confirm by pressing SET.
In the submenu of item 7 (Function), select function 7 with the
SELECT button. LED 7 lights up.
Confirm by pressing SET.
LED 7 lights up again.
settings
for
51
the
detector
channels,
exit