Programming of working time
The control unit is supplied by the manufacturer with the working time of the motor pre-set at 30 second. Should it be
necessary to reprogram the working time for the motor, then the operation must be carried out as follows:
1. Disconnect the battery.
2. Close the shutter.
3. Switch off power supply of the system.
4. Press and keep pressed the button PROG.
5. Supply power the system: the shutter begins its rising phase; once it reaches the desired position, let go of the
PROG key. It is recommended that the time memorised be a few seconds longer than the time it takes for the
shutter to reach the end of its run.
6. Reconnect the battery
The operation may be repeated if a mistake is made during programming.
Programming of the remote control
During the programming procedure, 1 or 2 remote-control codes can be memorised. A single code produces a cyclical
movement (Up/Down); using two codes, the upward and downward motion can be controlled separately.
The remote-control transmission codes are programmed as follows:
1. Push the PROG key for 1 second. The Led LD1 will start to blink.
2. Send the first code with the remote control chosen. The Led LD1 shall start to blink rapidly.
3. Send the second code with the remote control chosen. The Led LD1 stays on, signalling that programming
has been completed.
Note: If the second code is not sent within 8 seconds, the control unit leaves the programming phase, selecting the
operating mode only with one remote-control code. This procedure can be repeated until a maximum of 25 remote-
control commands are memorised. If all 25 codes have been memorised by repeating the programming, then Led
LD1 signals shall begin blinking, signalling that no further memorisation operations are possible.
Remote-control commands can also be memorised without using the PROG key on the control unit. The procedure is
as follows:
1. Take a remote-control command already memorised and send the code to the control unit, keeping the button
pressed down for more than 20 seconds.
2. The control unit begins programming, triggering the blinking light and making some movements of the shutter;
new codes may be programmed during this phase by proceeding exactly as described above starting from the
second point.
Note: if no code has been memorised yet, then the remote programming phase may be activated by any remote
control command.
Flashing light or courtesy light
The control unit has a 230Vac 40W max. outlet for connection of a flashing light or courtesy light. The control unit is
supplied by the manufacturer with the Flashing Light function enabled (S1 Jumper inserted). Under the blinking mode,
the 230 Vac outlet is activated every time the automation is in movement, for the duration of the motor time. To enable
the courtesy light, remove the Jumper S1. When the courtesy light is activated, the control unit enables the 230V
outlet for 180 second every time an opening command is issued.
Pause time: (Programming of the automatic closing time, max. 90 seconds)
The control unit is supplied by the manufacturer without automatic closing.
To enable the automatic closing function, insert the jumpers S2 and S3 following the logic shown in the table 1.
If don't want the automatic closing, remove the jumpers S2 and S3
Cancellation of all the codes in the memory:
Cancellation of all the codes in the memory is carried out as follows:
1. Push the PROG key for 25 seconds.
2. The led LD1 goes on for a few seconds, then goes off signalling cancellation of the codes.
WARNING
Batteries contain pollutant elements, must be disposed of in accordance with environmental laws. The
manufacturer advise to use a specifical disposal system.
For maintenance of the battery see pag.11

DECLARATION OF CONFORMITY

The manufacturer declares that the LS 1299 is conform to the specifications in the Directives R&TTE 99/5/EC, EMC
2004/108/EC, LVD 2006/95/EC.