WARNING: DISCONNECT THE BATTERY CABLES BEFORE OPERATING
ON CONTROL UNIT. (See Pic 2 on page 2)
IMPORTANT NOTICE
The manufacturer reserves the right to introduce modifications without prior notice; the manufacturer does not bear
any responsibility for damage or injury caused by improper use or wrong installation. Before installing and
programming the control unit, carefully read this instruction manual.
- This instruction manual shall only be used by technical staff specialized in automation installation.
- No information contained herein may be of interest to final users.
- All maintenance or programming operation shall only be performed by skilled technical staff.
AUTOMATION SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT EUROPEAN STANDARDS:
EN 60204-1 (Safety of Machinery, electrical equipments of machines, part 1: general rules).
EN 12445 (Safety in use of power operated doors - testing methods).
EN 12453 (Safety in use of power operated doors - requirements).
- The installer shall provide for the installation of a device (for ex. magnetothermic switch) granting the omnipolar
sectioning of the power supply mains.
- Standards require a minimum contact separation of 3 mm at each pole (EN60335-1).
- Use fittings complying with protection rating IP44 or higher to connect flexible and not flexible pipes or fairleads.
- Installation requires deep knowledge of electricity and mechanics and shall only be carried out by skilled
professionals who shall issue a type. A Declaration of Conformity for the complete installation (EC 89/392 Machinery
Directive, Appendix IIA).
- Following standards for motorised doors shall apply:
EN 12453, EN 12445, EN 12978 and local regulations.
- The electrical system for the automation shall be done to perfection and shall meet current standards.
- Connect the motor earth wire to the earthing system of the power supply.
NOTES FOR THE INSTALLER
1. If more than one control box is installed, the distance between control boards shall be at least 3 meters to allow the
correct working of the radio receiver.
2. The control station has no sectioning device for 230 Vac power supply mains. A special sectioning device shall be
provided for during installation.
3. Use fairleads for control station wires.
4. When not in use, the usually closed inputs (NC) shall be connected with cordless plug
OPERATING CHARACTERISTICS
Step-Step Operation: When a one-channel remote control ( LD1 Led on ) or low-voltage button is used to operate
the shutter, the following functional sequence occurs: the first impulse triggers the opening, up to expiration of the
motor time; the second impulse triggers the closing of the shutter. If an impulse is sent before the expiration of the
motor time, then the control unit stops the motion; a further command triggers resumption of the motion, but on the
opposite direction.
Automatic closing: With the control unit, the shutter can be closed in the automatic mode without sending any
additional commands. The set-up for this mode of operation is described in the paragraph "programming of the control
unit".
Security device: With the control unit it is possible to power and to connect security devices, such as photocells,
pneumatic slats (NC) etc.. The addition does not result in variations in operation during the opening phase, while it
leads to an inversion of the motion during the closing. If not utilised, this input must be bridged.
PROGRAMMING OF THE CONTROL UNIT
Programming of the control board is performed using the buttons PROG and the three Jumper S1, S2, S3.
PROG Button is used for programming the remote control codes, motor time and the central unit reset.
Logic of the Jumper S1, S2, S3:
JUMPER
S1
S2
S3
S2+S3
INSERTED
FLASHING LIGHT
AUTOMATIC CLOSING 30s
AUTOMATIC CLOSING 60s
AUTOMATIC CLOSING 90s
Table 1
NOT INSERTED
COURTESY LIGHT
7
/
/
/