English
1. General instructions
Anyone involved with the assembly, operation, maintenance or repair of the product should read and be aware
of the contents of the instruction manual.
National standards and safety regulations must be observed.
2. Use and intended purpose
The full body shower is used for washing specifically the body.
The full body shower provides swift assistance when initial steps are being taken to combat possible contamina-
tion of the body with substances which present a health hazard.
3. Technical details
The emergency shower fixes to the floor, it consists of an eye and face shower, which is available without a
basin or with either a stainless steel or a plastic basin and a full body shower with either a plastic (model G
1991) or a stainless steel shower head.
The shower heads for the eye and face shower have a self-regulating water flow, a filter and protective
caps.
The eye shower fixes onto a tap, there is a switch on the bottom of the tap to ensure that the tap can be used
independently of the shower.
4. Assembly
1.
Fit the floor flange (A) in position. For this purpose, drill 3 x 12 mm dia. holes in the floor. Fasten the flange
down with wall plugs and 10 mm screws (with the G 1991 type, drill 4 x 16 mm dia. holes and fasten the
flange down with 14 mm wall plugs and 12 mm screws).
2.
Fit the stop end (B) and the outlet tee (C).
3.
Screw on the pipe (D) and the mounting unit (E) for the wash basin. Position the mounting unit so that us-
ers will have good access to the basin.
4.
Then screw on the pipe (F) and the inlet tee (G). Screw on the tee in such a way that it can be connected to
the water supply. If on the other hand the vertical connection at the top (I) is going to be used, seal off the
tee (G) with the square-drive plug.
5.
Screw on the pipe (H) and then screw on the inlet tee (I) with its reduced branch pointing forward, so that
the shower can be mounted at the correct point. If the horizontal inlet at the rear (G) is going to be used,
seal off the tee (I) with the square-drive plug.
6.
Then screw on the pipe (J) and emergency shower valve (K). Screw to the latter the pipe (L), the elbow (M)
and the shower head (N).
7.
Place the dished washer (O), the rubber seal (P) and the basin (Q) on the thread. Centre the parts to en-
sure that there is a water-tight seal.
8.
Screw the outlet fitting (R) as far as possible down the threaded stem. If necessary, turn the basin clock-
wise to screw the outlet fitting (R) down the threaded stem.
9.
Screw the spray head down onto the threaded stem. Position the spray heads so that they are easily ac-
cessible.
10. Secure the entire unit to the floor and/or wall to give it stability.
11. Check the operation of the unit.
Important:
The pipes are all taper-threaded, so you will need tightly mated connections or Teflon thread sealing tape to