NATURAL GAS CONVERSION KIT
!
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with
Real Flame's instructions and all applicable codes and requirements of the Authority
Having Jurisdiction. If the information in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the operation of
the converted appliance is checked as specified in the manufacturer's instructions
supplied with this kit.
!
This conversion kit is for changing a Liquefied Petroleum (LP) fire table into a Natural Gas
NOTE
fire table.
1
Natural Gas Hose and Quick Disconnect
2
NG Orifice Spud 3.9mm
3
Primary Air Mixer Sleeve
1
2
PARTS LIST 00023106G
4
5
3
1
Conversion Plaque
Cable Kit
4
Conversion for Model Numbers
C539, C1600, C9620, C11842, C569, C9640,
C9650, C568, C9690, C11700, C11704, C11751,
C11752
T his re table has been
conver ted to use N atu ral G as.
C et te table a été
c o nvertie en gaz n
F or technical support call: 1-800-654
Type of Gas / Type de gaz: NG/Natural Gas
Normal Hourly Input/Entrée horaire normal:
50,000 BTU/Hr. (14.65 kW)
Manifold Pressure/Pression d'admission:
7.0" water column (1.74 kPa)
The minimum inlet pressure for this fire table is:
3.5" water column (0.87 kPa)
The maximum inlet pressure for this fire table is:
10.5" water column (2.61 kPa)
This appliance was converted on
Cet appareil a été converti le
to Natural Gas with Kit No._______________________
en gaz naturel avec le kit no.
by___________________________________________,
par
(Name and address of organization making this conversion)
which accepts the responsibility that this conversion has
been properly made.
qui accepte la responsabilité que cette conversion a été faite correctement.
After converting this fire table, this plaque must be hung from the
center of the control panel with the provided cable.
Après avoir transformé cette table à feu, cette plaque doit être
suspendue au centre du panneau de commande avec le câble fourni.