Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
W175-0408, Propane to Natural Gas Includes;
STEP MOTOR / REGULATOR
#37 BURNER ORIFICE (PRIMARY)
#52 BURNER ORIFICE (SECONDARY)
CONVERSION DATA LABEL
NATURAL GAS PILOT INJECTOR
This conversion kit shall be installed by a qualifi ed service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fi re, explosion
or production of carbon monoxide may result causing property damage, personal injury or
loss of life. The qualifi ed service agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation of the converted appliance is
checked as specifi ed in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance
may result in property damage or personal injury.
CAUTION: Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.
1. Remove the safety screen, glass door and media.
2. Remove the 12 screws (6 per side) that secure the media tray and burner assembly in place. Lift this assembly up and out of the appliance.
3. Using a deep socket wrench, remove the orifi ce from the primary burner (left side, 30" burner) and replace with the orifi ce supplied (#37 for NG,
#52 for LP). Remove the orifi ce from the secondary burner (right side,12" burner) and replace with the orifi ce supplied (#52 for NG, #59 for LP).
4. Remove the two screws from the valve regulator and remove the regulator, replace with the one supplied, refer to Figure 1. Adjust the air shutter
for the primary and secondary burner according to the table located on the back of this page.
Figure 1
REGULATOR
5. Remove the pilot hood from the pilot assembly by pulling vertically. Use a
the injector. Replace the pilot injector with the one supplied. Re-assemble the pilot hood onto the
assembly ensuring key position for proper alignment.
6. The conversion data label must be fi lled out and attached adjacent to the valve.
7. Re-install the burners and media tray assembly. Turn on the electrical supply to the appliance.
FUEL CONVERSION KITS FOR MODEL
LV50N / LV50N2
These kits are for use at altitudes of 0 to 4500 feet.
1
1
1
1
1
Continued on reverse
W175-0409, Natural Gas to Propane Includes;
STEP MOTOR / REGULATOR
#52 BURNER ORIFICE (PRIMARY)
#59 BURNER ORIFICE (SECONDARY)
CONVERSION DATA LABEL
NATURAL GAS PILOT INJECTOR
5
/
" Allen key to unscrew
32
1
1
1
1
1
PILOT
HOOD
PILOT
INJECTOR
W415-1508 / B / 05.02.16

Publicité

loading

Sommaire des Matières pour Wolf Steel LV50N

  • Page 1 INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER. CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED. FUEL CONVERSION KITS FOR MODEL LV50N / LV50N2 These kits are for use at altitudes of 0 to 4500 feet. W175-0408, Propane to Natural Gas Includes;...
  • Page 2: Venturi Adjustment

    8. Turn on the gas supply. Then light the pilot to ensure the gas lines have been purged. 9. Check for gas leaks by brushing on a soap and water solution. Refer to the lighting instructions in your installation manual. Do not use open fl ame. Once all systems have been checked, replace the glass media.
  • Page 3: Pressure Adjustment

    PRESSURE ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Inlet pressure can be checked by turning screw (A) counter-clockwise until loosened and then placing pressure gauge tubing over the test point. Gauge should read 7” (minimum 4.5”) water column for natural gas or 13”...
  • Page 4: Ensemble De Conversion Pour Le Modèle Lv50N / Lv50N2

    7. Réinstallez le brûleurs et l’assemblage du plateau de braises vitrifi ées. Rétablissez l’alimentation DE VEILLEUSE électrique au l’appareil. Suite au verso W415-1508 / B / 05.02.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • télécopieur(705)722-6031 • www.napoleonfoyers.com...
  • Page 5: Réglage Du Venturi

    à se détacher des orifi ces du brûleur. La fl amme peut ne pas être jaune immédiatement; allouez de 15 à 30 minutes pour que la couleur fi nale de la fl amme se stabilise. BRÛLEUR CLOSE FERMÉ PRINCIPALE RÉGLAGE DU OPEN OUVERTE BRÛLEUR VOLET D’AIR SECONDAIRE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • télécopieur(705)722-6031 • www.napoleonfoyers.com...
  • Page 6: Ajustement De La Pression

    DE FLAMME LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DU THERMOCOUPLE ET DE LA THERMOPILE DE 3/8” À 1/2”. W415-1508 / B / 05.02.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • télécopieur(705)722-6031 • www.napoleonfoyers.com...

Ce manuel est également adapté pour:

Lv50n2