Greenlee PDMM-20 Manuel D'instructions page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications (cont'd)
Measurement Categories:
Cat II, 450 V
Cat III, 300 V
Sensing: Average sensing, RMS calibrated
Safety: Double insulation with the lead tip insulation CAP per
IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0,
IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 2.0 and
CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 300V &
CAT II 450V. Without the test lead tip insulation CAP, to
CAT II 450V.
CENELEC Directive: Conform to CENELEC Low-voltage directive
2014/35/EU and Electromagnetic compatibility directive
2014/30/EU
* Noise rejection is the ability to reject unwanted signals, or noise.
• Normal mode voltages are AC signals that can cause inac-
curate DC measurements. NMRR (Normal Mode Rejection
Ratio) is a measure of the ability to filter out these signals.
• Common mode voltages are signals present at the COM
and + input terminals, with respect to ground, that can
cause digit rattle or offset in voltage measurements. CMRR
(Common Mode Rejection Ratio) is a measure of the ability
to filter out these signals.
18

Publicité

Table des Matières
loading

Table des Matières