Installation to Double Wood Stud Wall
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
• When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the
woods studs are a minimum of 2" x 4" nominal size. When installing to more than one stud, ensure the spacing
between studs is at least 16" but does not exceed 24". Do not install over gypsum board thicker than 5/8".
Wall plate (A) can be mounted to two studs that are 16", 20", or 24" apart. Use a stud finder to locate the edges
1
of the studs. Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical
line down each stud's center. Place wall plate on wall as a template. The top mounting slots should be located
X" above the desired display center as shown in figure 1.1 and 1.2. Level plate, and mark the center of the four
mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill four 5/32" (4mm) dia. holes
2" (51mm) deep. Make sure that the wall plate is level and secure it using four wood screws (C) as shown
in figure 1.3.
X
X
X
NOTE: When mounting wall
plate (A) to two studs, do not
use center mounting holes or
outer mounting holes.
fig. 1.1
X
X
X
X"
A
C
WARNING
( )
Y
X
X =
+ 1.75"
X
2
Y = distance between
X
display mounting holes
4 of 29
DISPLAY
Y"
fig. 1.3
ISSUED: 04-01-11 SHEET #: 203-9029-4 02-27-14
fig. 1.2