PROGRAMMING FLOWCHART
Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Keypad
Proximity
Reader
Reader
Present Card/Tag
before the Reader*
Notes
Memory Position for User Code is always 2 digits
* no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay 1 (10A) in Latch Mode assuming Master Code = 000
Press 000B + 0 + 05 + 12345 + A + 3 + 05 + 1 + A + 1 + 00 + A + B.
Ex. 2: To assign User Code "6789" at Memory Position "6" and Relay 2 (2A) that activates for 5 seconds assuming Master Code = 000
Press 000B + 0 + 06 + 6789 + A + 3 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
Above
Warranty : XPR warrants its products to be free from defects in material and workmanship for 24 months from the date of shipment. The product is to be installed in
accordance with XPR's instructions and the unit should not be modified or tampered with. XPR does not assume any responsibility for damages arising from misuse of
the product. XPR's sole responsibility is limited to the repair or replacement when the product is sent to XPR's facility.
ENTRIX
Enter "Master Code" OR "000" (if first time use)
1 small beep + 1 long beep + Yellow LED is 'on'
Change
Assign Output
Master code
Press (0)
+
Memory position from
Memory
position (00)
Press (1) for Relay 1
Press (2) for Relay 2
Press (12) for
both outputs
Enter new code
(1 to 8 digits)
See: Assign Output
above
Start
Validate by pressing (B)
No
Validation OK?
Yes
Set Output Timer
Press (3)
+
Pulsed Mode (01 to 99 sec):
Relay 1 (10A):
(01 to 99)
Press (1) + (from 01 to 99)
+
Relay 2 (2A):
OR
Press (2) + (from 01 to 99)
OR
Latch Mode (ON/OFF):
Press (1) or (2) + (00)
Press A to validate
Validation
No
OK?
Yes
Press B (Yellow LED is 'off')
End
See: Set Output Timer
6
Multiple small beeps
+
Yellow LED blinks rapidly
Delete Single
Code
Press (9)
+
Memory position from
(01 to 99)
OR
above
Delete All Codes
Press (8)
+
(99)