THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE
SHALL EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not,
you will need a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please
consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside
in observation of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified
by a professional and must also observe the relevant national regulations. This Flue liner should not be shared
with other devices (see Table 1.1 Technical specifications).
2.3 Type of appliance "Vermiculite" home plate at the bottom, sides and baffle plate, fire grate, ash pan and ventilation
set incorporated. The fireplace comes ready to install. All the inner can be removed if desired, for easier transportation
and installation.
2.4. Safety distances.
Anything fragile or flammable (textile, electronics, wood, paper wall, glass, chalk...) should be separated of the appliance
and respected the safety distances described in 1.1 Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility
of hot air that expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.5 Air supply. Air should be provided to the room where the appliance is installed. This is especially relevant when
outside air is not used and also when the door is opened for reloading with logs. This entry cannot be less than 225
cm2. Also note the simultaneous operation with other ventilation devices and / or heating such as exhaust fans, heat
pumps, etc. In these cases, the extraction must be compensated with a corresponding air entry from outside.
2.6 Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas
Rocal, S.A. We also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3. INSTALLATION
3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED
document. WARNING: The second part of the deflector shield must be adjusted or removed in case there is a bad
draught. In case of removal, follow the steps 'D.5' to 'D.8'. To adjust the door lock, follow the steps 'D.9' and 'D.10'. To
change the door opening, follow the steps described in the images 'D.11' to 'D.18'.

. USE AND OPERATION

4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels
other than those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs
are authorized as fuel and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the
height of the reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a
protection glove.
4.2 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum
load allowed by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed
inside (such as gloves, spray paint ...)
4.3. Combustion control. The appliance has mechanisms to regulate combustion.
4.3.1. Primary register. The primary register is used to control the air entering the combustion chamber through the
base of the fire. The primary register should be used mainly for lighting and, if necessary, to aid combustion. To locate
the register control handle and to know how to use it see picture "D.2" on page 7 of the ANNEXED document.
4.3.2. Secondary register. The secondary register is used to control the air entering the combustion chamber from the
top. The secondary register is used as combustion intensity adjustment. To locate the register control handle and to
know how to use it see picture "D.3" on page 7 of the ANNEXED document.
4.4 Fire lighting. To light the fire, use suitable materials for this purpose, such as heat pads, paper, dry and thin
branches. DO NOT USE GASOLINE, SOLVENTS OR ALCOHOL. To see the correct position see picture "C.5" on page
9 of the ANNEXED document, then light the fire using a suitable material. Once the fire is lit keep the door and the