Operating The Appliance; Control Panel; Switching On The Appliance For Heating; Switching On The Appliance For Air Circulation - Dru Verwarming KAMARA 7KW Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTRUCTIONS FOR INSTALLATION
Fig. 10

6. Operating the appliance

6.1 Control panel

The control panel is located under the cover at the top of
the appliance.
The cover is provided with a lock.
On the panel you will find (see fig. 11)
a)
summer/winter switch;
b)
thermostat;
c)
lock-out mode;
d)
reset button;
e)
fuse.
SCREWS
Fig. 11
sub a)
"0" position
In the position "0", the appliance is switched off
winter position
In the winter position, you have 2 options:
1) The appliance is controlled by an external clock and/or
thermostat;
2) The appliance is only controlled by the internal
thermostat.
summer position
In the summer position the appliance will operate
independently from an external clock and/or thermostat.
In this position, only convection air (= surrounding air) is
test point
circulated.
Sub b)
The (internal) thermostat can be set between 5 ºC
and 35 ºC.
The green led of the thermostat will light if the appliance
is switched on and the thermostat is "not requesting".
(behind cover screw)
The red led will light if the appliance is switched on and
the thermostat is "requesting".
test point
Sub c)
In case of a malfunction, the red lamp of the lock-out
mode will light.
Sub d)
In case of a malfunction, the appliance can be reset by
using the reset button.

6.2 Switching on the appliance for heating

• Set the external clock and/or thermostat, if present.
• Set the thermostat to the required temperature.
• Set the switch to the winter position.
Caution About approximately 30 seconds after
!
6.3 Switching on the appliance for air
circulation
• Set the switch to the summer position.
The appliance will continuously circulate convection air
(= surrounding air).

6.4 Switching off the appliance

• Set the switch to the "0" position.

7. Final check

To check that the appliance is operating correctly and
safely, you must proceed as follows before the appliance is
used.

7.1 Gastightness

!
Caution All connections must be gastight.
!Caution
• Check the connections for gastightness.
• Make the connections gastight, if necessary.
12
igniting the burner, the convection fan
should switch on.
The louvre openings will release warm air.
The supply pressure to the gas control
valve cannot exceed 50 mbar.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kamara 12kwKamara 16kw

Table des Matières