BOARD LAYOUT AND TERMINAL BLOCKS CONNECTION
The " Hydraulic unit " output is not protected :
The following protection must be installed ahead of the " Power Supply " input :
-Motor circuit breaker type GV2 5,5A MAX.
PUT THE RAMP ON LOADING POSITION
By means of the push button
The lip extends automatically on upper end position.
As soon as the lip is fully deployed, the push button can be released.
The ramp drops automatically on loading position ( floating position )
PUT THE RAMP ON REST POSITION
By means of the push button
As soon as the lip is fully folded and the ramp is over the rest position, the push button can be released.
Next, the ramp descends automatically on rest position.
To deactivate the Electro-valve, the power supply must be switched off.
NOTPIC201AS-T-01 4/8

Operating

( dead man operating ), the loading ramp rises.
( dead man operating ), the ramp rises while the lip folds.
Fuses Values
F1
500V/6.3AT/HPC 5x20
F2
500V/6.3AT/HPC 5x20
F3
500V/6.3AT/HPC 5x20
F4
250V/1.6 AT 5x20
Terminal blocks and switches
description
Blocks 1-2 : Door Contact (LS...)
B1
Blocks 3-4 : Wheel-Lock Contact
B2
DC Valve output.
(Blue)
Voltage Value selection by SW1
B3
AC Valve output.
(Orange)
Voltage Value selection by SW1
Power supply input
B4
(400V three-phase)
B5
Hydraulic unit output
Selection of the valves outputs
SW1
voltage value : 12V or 24V
Connector for front-face buttons.
CM1
Already connected at the factory.